JTAlert with WSJT-X
JTAlert sits beside WSJT-X and listens on the same UDP reporting channel. It adds audio/visual alerts for wanted callsigns, grids, and countries, and can forward QSOs to LoTW, QRZ, Club Log, and other services.
Home: hamapps.com — JTAlert
What it is (and is not)
JTAlert is a companion, not your primary field log for POTA activations. WSJT-X writes wsjtx_log.adi; JTAlert can mirror contacts to online services. For park references, you still need correct MY_SIG_INFO in the export you upload to pota.app — JTAlert does not replace Polo or N3FJP for that job.
Use JTAlert when:
- You hunt from home and want “new DXCC” or “new grid” bells.
- You want automatic LoTW uploads for FT8 QSOs without manual TQSL steps.
- You run WSJT-X without GridTracker but still want structured alerts.
Skip JTAlert in the field if:
- You already run GridTracker alerts and do not need duplicate chimes.
- Phone battery and laptop CPU are tight — one UDP listener is enough.
Basic setup
- Install JTAlert and WSJT-X (matching major versions when possible).
- WSJT-X → Settings → Reporting → enable UDP Server on
127.0.0.1:2237. - Launch WSJT-X first, then JTAlert. JTAlert should show “connected.”
- JTAlert → Settings: set your callsign to match WSJT-X exactly (including
/Por portable suffix if you use one).
Rig control note
If N3FJP AC Log also runs, N3FJP’s digital setup docs recommend rig control = none in N3FJP when FLdigi or JTAlert owns CAT — otherwise two programs fight the serial port. See N3FJP digital setup.
Running JTAlert + GridTracker together
Both can listen to WSJT-X. Two common patterns (GridTracker groups.io discussion):
Option A — multicast: WSJT-X Reporting tab uses a multicast address. JTAlert auto-detects; GridTracker → Settings → General → enable Multitask.
Option B — forward: WSJT-X on 2237 → GridTracker receives and forwards on 2238 → JTAlert listens on 2238. Launch GridTracker before JTAlert.
Warning: Avoid uploading the same QSO twice to LoTW from both programs. Pick one upload path.
Pick one alert voice pack. Two programs shouting “CQ DX” at once is a feature nobody needs.
POTA-specific use
JTAlert has no special POTA mode. Practical approach:
- Hunters: enable alerts for callsigns on your “needed parks” list if you maintain one in JTAlert’s wanted setup; otherwise watch pota.app and GridTracker POTA layer.
- Activators: JTAlert is optional. Your job is WSJT-X logging + master ADIF with park tags. Consider JTAlert off during activations to save CPU.
For FT8 hunter etiquette (split TX, grid omission): Hunt and WSJT-X.
Habits / gotchas / checklist (JTAlert)
Related
Notes & edits
Comments and proposed markdown sit in a queue. Nothing is public until it is reviewed. How this works.